Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
|
|
|
|
Generator Set Specifications
- Maximum Rating
- 65.0 kVA
- Minimum Rating
- 65.0 kVA
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1,500 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- Cat® C3.3, In-line 3, 4-cycle diesel
- Bore
- 4.1 in
- Stroke
- 5 in
- Displacement
- 201.4 in³
- Compression Ratio
- 17.25:1
- Aspiration
- Turbocharged
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length - Maximum
- 89.7 in
- Width - Maximum
- 35.4 in
- Height - Maximum
- 52 in
- Dry Weight - Genset (maximum)
- 2,273 lb
Standard Equipment:
-
- Engine
-
- C3.3, Inline 3 cylinder, 4 stroke diesel
-
- Genset Control
-
- GCCP 1.1
-
- Governor
-
- Mechanical governor
-
- Alternator
-
- A Frame standard alternator
-
- Fuel Storage
-
- Single wall 8 hour fuel tank
-
- Enclosure
-
- Cat GC enclosure
-
- Air, Cooling & Exhaust
-
- Enclosure silencer
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Certification
-
- Certificate of Conformance
- Australia, CIS, Gulf Certification
-
- Alternator Requirements
-
- Space heater
-
- Auxiliary Supply Voltage
-
- 120V
-
- Fuel Storage
-
- Dual wall 8 hour fuel tank
- Single wall tank with containment
- Low fuel level alarm
- Low fuel level shutdown
- High fuel level alarm
-
- Genset Control
-
- Battery charger
- Volt free contacts for common alarm
- Volt free contacts for genset running
- Panel mounted audible alarm
- Earth fault
- Earth leakage
- USB to RS485 Communications device
- Emergency stop with key
- Battery
- Standby Pack (Smart Jacket water heater, Battery charger)
- Coolant heater
- Low coolant level shutdown
-
- Circuit Breaker
-
- 3 Pole Circuit breaker 63A
- 3 Pole Circuit breaker 80A
- 3 Pole Circuit breaker 100A
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 80A
- 4 Pole Circuit breaker 63A
- 4 Pole Circuit breaker 100A
- 4 Pole Circuit breaker 125A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 200A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
-
- Testing & Packaging
-
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
Specifications
Generator Set Specifications
- Maximum Rating
- 65.0 kVA
- Minimum Rating
- 65.0 kVA
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1,500 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- Cat® C3.3, In-line 3, 4-cycle diesel
- Bore
- 4.1 in
- Stroke
- 5 in
- Displacement
- 201.4 in³
- Compression Ratio
- 17.25:1
- Aspiration
- Turbocharged
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length - Maximum
- 89.7 in
- Width - Maximum
- 35.4 in
- Height - Maximum
- 52 in
- Dry Weight - Genset (maximum)
- 2,273 lb
Standard/Optional Features
Standard Equipment:
-
- Engine
-
- C3.3, Inline 3 cylinder, 4 stroke diesel
-
- Genset Control
-
- GCCP 1.1
-
- Governor
-
- Mechanical governor
-
- Alternator
-
- A Frame standard alternator
-
- Fuel Storage
-
- Single wall 8 hour fuel tank
-
- Enclosure
-
- Cat GC enclosure
-
- Air, Cooling & Exhaust
-
- Enclosure silencer
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Certification
-
- Certificate of Conformance
- Australia, CIS, Gulf Certification
-
- Alternator Requirements
-
- Space heater
-
- Auxiliary Supply Voltage
-
- 120V
-
- Fuel Storage
-
- Dual wall 8 hour fuel tank
- Single wall tank with containment
- Low fuel level alarm
- Low fuel level shutdown
- High fuel level alarm
-
- Genset Control
-
- Battery charger
- Volt free contacts for common alarm
- Volt free contacts for genset running
- Panel mounted audible alarm
- Earth fault
- Earth leakage
- USB to RS485 Communications device
- Emergency stop with key
- Battery
- Standby Pack (Smart Jacket water heater, Battery charger)
- Coolant heater
- Low coolant level shutdown
-
- Circuit Breaker
-
- 3 Pole Circuit breaker 63A
- 3 Pole Circuit breaker 80A
- 3 Pole Circuit breaker 100A
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 80A
- 4 Pole Circuit breaker 63A
- 4 Pole Circuit breaker 100A
- 4 Pole Circuit breaker 125A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 200A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
-
- Testing & Packaging
-
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor