fbpx

DE55 GC Generator Set (60 Hz) 16821

DE55 GC Generator Set (60 Hz)
16821 DE55 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Frequency
60 Hz
Maximum Rating
50 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Frequency
60 Hz
Maximum Rating
50 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Minimum Rating
50 ekW
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
76.6in
Width - Maximum
34.3in
Height - Maximum
48.7in
Dry Weight - Genset (maximum)
2114lb

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Emergency stop with key
    • Earth leakage
    • USB to RS485 Communications device
    • Earth fault
    • Panel mounted audible alarm
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Coolant heater
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Frequency
60 Hz
Maximum Rating
50 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Minimum Rating
50 ekW
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
76.6in
Width - Maximum
34.3in
Height - Maximum
48.7in
Dry Weight - Genset (maximum)
2114lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Emergency stop with key
    • Earth leakage
    • USB to RS485 Communications device
    • Earth fault
    • Panel mounted audible alarm
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Coolant heater
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF