Maximum Rating
163.9 kVA
Minimum Rating
163.9 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
163.9 kVA
Minimum Rating
163.9 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1,500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
Stroke
5.3 in
Displacement
427.8 in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9 in
Width - Maximum
44.6 in
Height - Maximum
65.6 in
Dry Weight - Genset (maximum)
1,834 lb

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • High fuel level alarm
    • Single wall tank with containment
    • Low fuel level shutdown
    • Low fuel level alarm
  • Alternator Requirements
    • Space heater
  • Genset Control
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Battery charger
    • Panel mounted audible alarm
    • Earth leakage
    • USB to RS485 Communications device
    • Earth fault
    • Emergency stop with key
    • Coolant heater
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Low coolant level shutdown
  • Circuit Breaker
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 400A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
163.9 kVA
Minimum Rating
163.9 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1,500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
Stroke
5.3 in
Displacement
427.8 in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9 in
Width - Maximum
44.6 in
Height - Maximum
65.6 in
Dry Weight - Genset (maximum)
1,834 lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • High fuel level alarm
    • Single wall tank with containment
    • Low fuel level shutdown
    • Low fuel level alarm
  • Alternator Requirements
    • Space heater
  • Genset Control
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Battery charger
    • Panel mounted audible alarm
    • Earth leakage
    • USB to RS485 Communications device
    • Earth fault
    • Emergency stop with key
    • Coolant heater
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Low coolant level shutdown
  • Circuit Breaker
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 400A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF