fbpx

DE150 GC Generator Set (50 Hz) 16837

DE150 GC Generator Set (50 Hz)
16837 DE150 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
150 kVA
Minimum Rating
150 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
150 kVA
Minimum Rating
150 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4043lb

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Governor
    • Mechanical governor
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Alternator
    • A Frame standard alternator
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Genset Control
    • Volt free contacts for common alarm
    • Battery charger
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Earth leakage
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Low fuel level alarm
    • Single wall tank with containment
    • High fuel level alarm
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
150 kVA
Minimum Rating
150 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4043lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Governor
    • Mechanical governor
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Alternator
    • A Frame standard alternator
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Genset Control
    • Volt free contacts for common alarm
    • Battery charger
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Earth leakage
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Low fuel level alarm
    • Single wall tank with containment
    • High fuel level alarm
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF