New CAT Switchgear and Paralleling Controls

Cat Customizable Switchgear and Controls

Configuration
Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation
All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow
Application
LV and MV ( 208V - 38 kV) 50 / 60 Hz

Cat EGP Switchgear

Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation
Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application
LV and MV (208V - 38 kV)

Cat Switchgear

Configuration
IP4X
Operating Temperature
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths
600 mm for ABB Emax2 E2 1,600 - 2,500A. 750 mm for ABB Emax2 E4 3,200 - 4,000A. 1,200 mm for ABB Emax2 E6 4,000 - 6,300A.

Cat XLM Switchgear

Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation
Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application
LV and MV ( 208V - 38 kV

EMCP 4.4 Master Control Panel

Configuration
Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
Modes of Operation
Emergency standby, island, utility paralleling
Application
LV and MV (208V - 38 kV)

Engine Paralleling and Integration Control (EPIC)

Configuration
Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation
Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application
LV and MV (208V-27kV)

Why Quinn

Quinn Company is a top choice for purchasing CAT equipment. And here is why:

25 locations in Central, Southern California and AZ

25 locations in Central, Southern California and AZ

Most regional buyers can see, operate, and walk-around a machine within 48 hours of inquiry.

602 factory-trained technicians

602 factory-trained technicians

Quinn does not subcontract repair. Same technicians sell, service, and warranty.

99% of parts filled within 24 hours

99% of parts filled within 24 hours

Quinn stocks CAT genuine at every location and pulls from the CAT distribution network for the rest.

CAT Certified Operator Training, levels 1 to 3

CAT Certified Operator Training, levels 1 to 3

Reduces operator-error damage and lowers insurance loss claims on owned fleets. Available on-site or at Quinn's training facility.

CAT Financial Pre-Qual at Quote Stage

CAT Financial Pre-Qual at Quote Stage

Most buyers leave the quote conversation with a financing tier already attached.

Over 100 Years as a California CAT Dealer

Over 100 Years as a California CAT Dealer

Quinn has been a CAT dealer since 1919. The longest-tenured CAT dealer in the state.

Find a Quinn location near you

Our machinery and equipment company serves central & southern California, with customized solutions that drive progress. Contact the Quinn Company division you need for a free quote.