Maximum Rating
400 kVA
Minimum Rating
400 kVA
Emissions/Fuel Strategy
Non-Certified Emissions
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
400 kVA
Minimum Rating
400 kVA
Emissions/Fuel Strategy
Non-Certified Emissions
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C9.3B, I-6, 4-cycle diesel
Bore
4.53in
Stroke
5.87in
Displacement
567.5in³
Compression Ratio
16.5:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
Common Rail
Governor Type
ADEM™A6

Generator Set Dimensions

Length - Maximum
104.8in
Width - Maximum
44in
Height - Maximum
69.5in
Dry Weight - Genset (maximum)
5070.6lb

Standard Equipment:

  • Engine
    • C9.3B, Inline 6 cylinder, 4 stroke diesel
  • Air, Cooling & Exhaust
    • Standard air filter
  • Genset Control
    • GCCP 1.1
  • Governor
    • Adem A4
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Air, Cooling & Exhaust
    • 6" Elbow kit
    • Dual element air filter
    • 5-6" Exhaust adapter
    • Canopy silencer
    • 5" Elbow kit
    • 6" Elbow kit
    • 6" Muffler - 25 dBA attenuation
    • 5" Muffler - 10 dBA Attenuation
    • Single stage air filter
    • No muffler
  • Alternator Requirements
    • IP Standard @ 21 FUW A-Frame
    • Space heater
  • Auxiliary Supply Voltage
    • 240V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Circuit Breaker
    • 3 Pole Circuit breaker 800A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 1250A
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 800A
    • Overload via alarm switch on breaker
    • Neutral earth link
    • 3 Pole Circuit breaker 1250A
    • Auxiliary contacts
    • Shunt Trip
  • Enclosure
    • Cat GC enclosure
  • Fuel Storage
    • Low fuel level shutdown
    • Fuel level alarms
    • Low fuel level alarm
    • Single wall tank with containment 01
    • High fuel level alarm
    • Dual wall 8 hour fuel tank
  • Genset Control
    • PLG Cellular 4G E
    • Oil temperature displays
    • Coolant heater
    • Battery charger
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • PLG Cellular 4G U
    • Voltage adjust potentiometer
    • Low coolant temperature alarm
    • Speed adjust potentiometer
    • PLG Ethernet
    • Battery